What is K Factor in Flow Meters?

What is K Factor in Flow Meters?

In flow measurement, the "K factor" is not as well-known as other flow meters specifications. It refers to the calibration factor associated with volumetric, pulse output flow meters. It is a constant value used to convert the physical flow rate of a media into an electrical or mechanical signal that can be measured and monitored.

The K factor represents the relationship between the flow rate passing through the flow meter and the output signal generated by the meter. It is typically determined through calibration tests performed by the manufacturer or a calibration laboratory.

The formula to calculate flow rate using the K factor is: Flow Rate = K Factor × Output Signal.

Flow Meter K Factor

Is the K Factor Uniform for Different Flow Meters?

Different flow meters have different K factors due to their unique design, operating principles, and construction.

For example, in a turbine flow meter, the K factor is determined by the rotor design, the number of blades, and the geometry of the flow passages. In a magnetic flow meter, the K factor is influenced by the pipe size, the magnetic field strength, and the flow profile.

Does Flow Meter K Factor Remain Constant?

It's important to note that the K factor may vary under different flow conditions, such as media viscosity, temperature, and pressure. Therefore, it is crucial to consider the application-specific conditions and use the appropriate K factor for accurate flow rate calculations.

Do I Need to Know the K Factor for My Flow Meter?

Any unit with a pulse output only will either require a nominal K-Factor or an actual K-factor. The K factor is specific to each type and model of flow meter and is usually provided by the manufacturer and is required to calibrate the unit.

For some models the unit comes with a chart of empirically derived data. Other units will have a table with multiple points plotted as flow rate vs. output pulse to help linearize the output data. The K factor is specific to each type and model of flow meter and is usually provided by the manufacturer.

Units with an analog output, such as 4-20mA, and units with a 0-5 Vdc output will not require knowledge of the K factor.

Sample K Factor Flow Meter Chart

What Now?

Still need some help in undertanding K Factor and how it relates to your flow meter or choosing a flow meter for your application? Speak to or email one of our expert engineers and they would be happy to walk you through it.

Featured Products
DON
Oval Gear Positive Displacement Flow Meter
DON - Positive-Displacement Flow Meters

For Viscous Liquids | Up to 660 GPM | Up to 300° F | Up to 1,450 PSI | NPT or ANSI Connections | Batching and Totalizing | Bi-directional Capabilities | Top Seller

DON-H
High Pressure Oval Gear Flow Meter
DON-H - Oval Gear Flow Meter for High Pressures

Stainless Steel | Optional Batching & Totalizing | Viscosities up to 1,000 cP & Higher | Up to 5,800 PSI | 0.13...10.6 GPM

About KOBOLD

KOBOLD USA is a subsidiary of KOBOLD Messring GmbH, a world-leading instrumentation engineering business founded in Germany in 1980 by Klaus J. Kobold. With patented technology and superior service, the company quickly established itself as one of the global leaders in sensor and control systems with high quality products. The KOBOLD brand name became synonymous with superior quality and technological advancement in instrumentation engineering.

Have a Question?

We are instrumentation experts and would be happy to help you in any way we can with your technical questions. Our engineers offer decades of experience and expertise.

Other Members of the KOBOLD group
Heinrichs Henschen Mesura Unirota