Flow Measurement without Moving Parts Products

DOG - Oscillation Flow Meter for Gases
DOG - Oscillation Flow Meter for Gases
Range
0.12...12 to 60...6,000 m³/h (Air)
Fittings
DN25... 200 Flange, ANSI 1"...8"
Wetted Materials
Stainless Steel
Maximum Pressure
40 Bar
Maximum Temperature
248°F (120°C)
Accuracy
± 1.5 % of Measured Value (Air)
Output
Pulse Frequency, Digital Display for Flow Measurement & Totalization
DUC - Portable or Stationary Ultrasonic Flow Meter for Liquids
DUC - Portable or Stationary Ultrasonic Flow Meter for Liquids
Measurement Principle
Time-of-flight w/DSP (Transit Time Principle)
Flow Velocity Range
0...98 ft/sec
Pipe Size Range
3/8"...20 Feet
Temperature Range
-40...300 °F
Accuracy
up to 1% of Reading
DUK - Compact Ultrasonic Flow Meter
DUK - Compact Ultrasonic Flow Meter
Measuring Ranges
0.02...5 GPM to 0.6...160 GPM
Accuracy
± 0.7 % of Rate and ± 0.7 % F.S.
Fittings
½"...3" NPT or G (BSPP)
Material
Brass or 316 Stainless Steel
Maximum Temperature
194 °F
Maximum Pressure
230 PSIG
Turndown Ratio
250 to 1
Outputs
Analog, Frequency, Switching, Compact Electronics w/ Digital Displays, Batching and Totalizing Electronics
DVE - Multivariable Insertion Design Vortex Flow Meter
DVE - Multivariable Insertion Design Vortex Flow Meter
Process Connection
ANSI, DIN Wafer Flange or Threaded via Compression Fitting
Line Sizes
DN80...DN600, (3"...24")
Wetted Materials
316L St. Steel
Input Power
12-36 VDC (2 & 4 Wire), 85-240 VAC 50/60 Hz
Display
Alphanumeric 2 Line x 16 Character LCD
DVH - Multivariable Vortex Flow Meter
DVH - Multivariable Vortex Flow Meter
Fittings
1/2”...8” ANSI Flanges, 1/2"...4" ANSI Wafer
Wetted Materials
Housing/Bluff Body/Flanges - 316L St. Steel (Standard)
Input Power
12-36 VDC (2 & 4 Wire), 85-240 VAC 50/60 Hz
Optional Display
Alphanumeric 2 Line x 16 Character LCD
DVZ - Vortex Flow Meter and Switch
DVZ - Vortex Flow Meter and Switch
Range
0.13...1.2 GPM to 2.7...26 GPM
Fittings
¼"...1" NPT & G¼...G1
Fitting Material
Ni-Plated Brass, SS
Max. Pressure
145 PSIG / 290 PSIG
Max. Media Temperature
176 °F
Accuracy
± 2.5% of Full Scale
EPS - Magnetic Inductive Flow Meter for Conductive Liquids
EPS - Magnetic Inductive Flow Meter for Conductive Liquids
Measuring Range
0.5 m/s...10 m/s
Fittings
1/2” NPT, ½”…24” ANSI Flange
Lining Materials
Hard or Soft Rubber, EPDM, PTFE, or Ceramic
Max. Pressure
580 PSIG (Model Dependent)
Max. Temperature
300 °F (Model Dependent)
Accuracy
± 0.3% of Measured Value ± 0.01% (Q at 10 m/s)
HPC - High Performance Coriolis Flow Meter for Low Flows
HPC - High Performance Coriolis Flow Meter for Low Flows
Mass Flow Measuring Ranges
2...20 kg/h to 5...50 kg/h
Connections
1/2" NPT, Gyrolok, Swagelok
Accuracy (Liquid)
± 0.1% of Reading
Max. Pressure
5,800 PSI
Max. Operating Temperature
350 °F
KAH - Air Velocity Sensor
KAH - Air Velocity Sensor
Selectable Sensing Range
0 ... 2000 / 3000 / 4000 ft/min
Body/Housing Material
Polycarbonate
Media Temperature Range
-13 ...122 °F
Power Supply
24 VAC/VDC ± 20%
Signal Output
4-20 mA or 0-10 VDC
Media Humidity Range
5 ... 95 % RH (Non-condensing)
KAL - Temperature-Compensating Thermal Flow Switch for Water-Based Liquids
KAL - Temperature-Compensating Thermal Flow Switch for Water-Based Liquids
Switching Range
0.2...6.6 ft/s
Fittings
1/4"...1-1/2" NPT
Material
Brass, SS
Max. Pressure
1450 PSI
Max. Temperature
176/250 °F
Output
Relay Outputs for Flow and Temperature Monitoring
KAL-A - Thermal Flow Sensor for Water-Based Liquids
KAL-A - Thermal Flow Sensor for Water-Based Liquids
Sensing Range
0.16...6.6 ft/s (Water)
Fittings
1/2" NPT, 3/4" NPT, 1½" Tri-Clamp®
Wetted Material
304, 316-Ti SS
Max. Pressure
1450 PSIG (with NPT Connection)
Max. Temperature
176 °F
Repeatability
Approx. 1%
Output Signal
4-20 mA, 3-Wire (Non-Linear)
Optional Switch
PNP Transistor, 400 mA Max.
KAL-D - Compact Thermal Flow Switch for Water-Based Liquids
KAL-D - Compact Thermal Flow Switch for Water-Based Liquids
Switching Range
0.15...6.6 ft/sec (Water)
Fittings
¼" NPT, ½" NPT, M12 x 1, G¼, G½
Wetted Material
316-Ti SS
Maximum Pressure
580 PSIG
Max. Media Temperature
176 °F
Repeatability
± 2 %
Switch Output
PNP/NPN, N/O, N/C (Specified upon Ordering)
KAL-K - Thermal Flow Switch with LED Flow Trend Indication for Water-Based Liquids
KAL-K - Thermal Flow Switch with LED Flow Trend Indication for Water-Based Liquids
Switching Range
0.2...6.6 ft/s (Water)
Fittings
½" or 3/4" MNPT, 1½" Tri-Clamp®
Wetted Material
304 or 316-Ti Stainless Steel
Max. Pressure
1450 PSIG (with NPT Connection)
Max. Operating Temperature
250 °F
Input Power
24 VDC ± 10%, 110 VAC Optional
Output
NPN/PNP Transistor, N/O Relay Only w/110 VAC Version
KAL-L - Thermal Air Flow Switch
KAL-L - Thermal Air Flow Switch
Measuring Range
3.3...66 ft/sec (Air)
Fittings
½" NPT, Flange
Output
SPDT Relay, Max. 250 VAC / 1000 VA / 4A
Max. Pressure
120 PSIG
Max. Temperature
250 °F
Switching Accuracy
± 10% of Reading
KEC - Thermal Energy Flow Meter
KEC - Thermal Energy Flow Meter
Measuring Range
0.2...90 Nm³/h to 5...2840 Nm³/h (Air), Max. 224 Nm/s
Accuracy
±1.5 % of Reading ±0.3 % of Full Scale
Maximum Pressure
100 Bar
Maximum Temperature
180°C
Process Connection
G ½...G 2, ½"...2" NPT, DN15...80 PN40 Flange, ½"...3" ANSI Class 150 & 300
Wetted Material
1.4571 St. Steel, Glass
Output
Modbus RTU, 2x 4-20 mA, Modbus TCP, pulse, alarm
KEL - Heavy Duty Differential Pressure Flow Meters
KEL - Heavy Duty Differential Pressure Flow Meters
Measuring Range
0.1...0.5 to 400...2000 GPM
Fittings
½"...1½" NPT or BSP, 1/2"... 8 " ANSI or DIN Wafer
Body Material
Brass, Brass/Cast Iron or SS
Accuracy
±3 to ±5% FS (Depending on the Model)
Max. Temperature
150 °F to 480 °F (Depending on Model)
Max. Pressure
230 PSIG
KME - Compact Inline Flow Meter
KME - Compact Inline Flow Meter
Measuring Range
0.2...76.3 to 2.2...848 Nm3/h (Air)
Accuracy
± 3 % of Reading + 0.3 % of Full Scale
Maximum Pressure
16 Bar
Operating Temperature
-20…60 °C
Process Connection
½", ¾" & 1" BSP and NPT Threaded
Wetted Materials
Aluminum, Stainless Steel, Glass
Outputs
PNP Transistor Switch, Analog Current, Pulse
KMT - Thermal Mass Flow Meter
KMT - Thermal Mass Flow Meter
Measuring Range
0.32...63 Nm³/h to 263.4...263350 Nm³/h (Air)
Accuracy
±1.5 % of Reading +0.5 to +0.8% of Full Scale
Maximum Pressure
16 Bar
Maximum Operating Temperature
+80 °C
Process Connection
G ½...G 2 & ½...2" NPT with ball valve, R½ Threaded Version for DN65...700
Wetted Materials
Stainless Steel, Glass, Brass
Outputs
Analog Output / Switch Outputs / Pulse Outputs
KPL - Orifice Plate
KPL - Orifice Plate
Maximum Pressure
420 Bar (Class 2500 tmax +500 °C )
Maximum Temperature
500° C
Process Connection
DN 50 ... DN 600, 2" ... 24" ASME Flanged
Wetted Material
Stainless Steel, Carbon Steel, Others
MAS - Mass Flow Meter for Gases
MAS - Mass Flow Meter for Gases
Measuring Ranges
0...10 SCCM to 0...500 SLPM
Fittings
¼" NPT, ½" NPT, ¼"...½" Swagelok®
Body Material
Polyamide, Aluminum, SS
Max. Pressure
150 PSIG (Polyamide, Aluminum), 500 PSIG (SS)
Max. Media Temperature
120 °F
Accuracy
± 1.5% F.S. at 15...25°C & 5...60 PSIA
Input Power
12 VDC Standard, 24 VDC Optional
Output Signal (Linear)
0-5 VDC Standard, 4-20 mA Optional
MIK - Economical Magmeter
MIK - Economical Magmeter
Available Ranges
0.18...7.8 GPH to 9...180 GPM (Water)
Accuracy
± 2% of Full Scale
Repeatability
± 1% of Full Scale
Media Temp. Range
32...176 °F (140 °F Max. w/PVC Fittings)
Media Conductivity
Minimum 30 μS/cm (Minimum 200 μS/cm for Range Codes U0 & U1)
Maximum Pressure
145 PSIG @ 70 °F
Max. Pressure Drop
3.6 PSI @ 100% Rated Flow
Max. Viscosity
20 cSt for ranges U0...U8, 70 cSt for ranges UA...UH
Wetted Materials
PPS/SS/NBR, PPS/SS/FKM, PPS/Hastelloy®/NBR, PPS/Hastelloy®/FKM, PVDF/Hastelloy®/FFKM, PVDF/Tantalum/FFKM
MIM - All-Metal Electromagnetic Flow Meter for Conductive Liquids
MIM - All-Metal Electromagnetic Flow Meter for Conductive Liquids
Process Connection Range
1/4"...2" NPT, 1" or 2" Tri-Clamp
Connection Material
316L Stainless Steel
Maximum Pressure
230 PSIG
Maximum Temperature
284 °F
Housing Material
316L Stainless Steel
Accuracy
< ±(0.8% of Reading + 0.5% of Full Scale)
MIS - Economical Electromagnetic Flow Meter
MIS - Economical Electromagnetic Flow Meter
Measuring Range
2...277 GPM to 18...4,400 GPM
Max. Media Viscosity
100,000 cP
Process Connection
2", 3", 4", 6" or 8" ANSI Flange
Maximum Pressure
230 PSIG
Repeatability
± 0.2% of Full Scale
Protection
IP67
PIT - Insertion Magnetic Flow Meter
PIT - Insertion Magnetic Flow Meter
Pipe Diameter
150...2000 mm (6"...78")
Accuracy
± 1.5% of Reading, ± 0.5% of Span (at Reference Conditions)
Fitting
Insertion Weld Sleeve with ANSI or DIN Mounting Flange
Adjustable Span
1...10 m/s (3.3...33 Ft/Sec.)
PITe - Magnetic Inductive Flow Meter
PITe - Magnetic Inductive Flow Meter
Measuring Range
1...10 m/sec (3.28... 32.8 ft/sec)
Accuracy (>30% URV)
±1.5% of Reading
Maximum Pressure
230 PSIG to 90 °C (194 °F), 200 PSIG to 100 °C (212 °F)
Maximum Temperature
100 °C (212 °F)
Process Connection
Welding Stub and M52 x 2 Union Nut for 3" to 16" pipes
Wetted Material
Stainless Steel / PTFE, Hastelloy® Electrodes
Output
Analog with HART®, Pulse, and Status
RCD - Ultra-Rugged Differential Pressure Flow Meter
RCD - Ultra-Rugged Differential Pressure Flow Meter
Measuring Range
0.2...0.88 to 100...600 GPM (Water)
Fittings
½"...3" NPT
Body Material
Brass, 316-Ti SS
Max. Pressure
580 PSIG
Max. Temperature
176 °F / 212 °F
Accuracy
± 3 % FS
Display/Output
Analog Output, Digital Display, Switches
RCM - Direct Reading Flow Meter
RCM - Direct Reading Flow Meter
Accuracy
± 3% Full Scale
Measuring Ranges
0.3...2.0 GPH to 400...3000 GPM (Liquids) / 1.5...10 SCFH to 3000...20000 SCFM (Gases)
Fittings
¼"...3" NPT, ½"...8" Wafer
Body Material
Bronze, Monel or SS
Media Temperature
-30...212 °F (Standard)
Optional High-Temp Design
-80...350 °F
Maximum Pressure
180 PSIG (Standard)
Optional High Pressure Design
400 PSIG
TM - Universal, Special Purpose Coriolis Mass Flow Meter
TM - Universal, Special Purpose Coriolis Mass Flow Meter
Mass Flow Measuring Ranges
0.003...0.3 Lb./Min. to 220...2400 Lb./Min.
Sizes
¼"...3"
Accuracy (Mass Flow)
± 0.1% of Reading
Fittings
NPT, BSPP, SAE Thread; ANSI, DIN, JIS Flange, Others on Request
Max. Operating Temperature
Up to 500 °F (Depending on Model)
TMU - High Performance Coriolis Mass Flow Meter
TMU - High Performance Coriolis Mass Flow Meter
Mass Flow Measuring Ranges
2.2...22 Lb/Min. to 220...2200 Tons/Hr.
Line Size
¼"...10" Standard (to 16" Upon Request)
Accuracy
± 0.15% of Reading or Better
Fittings
NPT Thread, ANSI CL 150/300 Flange, Others Upon Request
Max. Pressure
580 PSIG Standard (Higher Upon Request)
Max. Operating Temperature
Up to 500 °F (Depending Upon Model)