Flow Measurement without Moving Parts Products

DOG - Oscillation Flow Meter for Gases
DOG - Oscillation Flow Meter for Gases
Range
0.12...12 to 60...6,000 m³/h (Air)
Fittings
DN25... 200 Flange, ANSI 1"...8"
Wetted Materials
Stainless Steel
Maximum Pressure
40 Bar
Maximum Temperature
248°F (120°C)
Accuracy
± 1.5 % of Measured Value (Air)
Output
Pulse Frequency, Digital Display for Flow Measurement & Totalization
DUC - Portable or Stationary Ultrasonic Flow Meter for Liquids
DUC - Portable or Stationary Ultrasonic Flow Meter for Liquids
Measurement Principle
Time-of-flight w/DSP (Transit Time Principle)
Flow Velocity Range
0...98 ft/sec
Pipe Size Range
3/8"...20 Feet
Temperature Range
-40...300 °F
Accuracy
up to 1% of Reading
DUK - Compact Ultrasonic Flow Meter
DUK - Compact Ultrasonic Flow Meter
Measuring Ranges
0.02...5 GPM to 0.6...160 GPM
Accuracy
± 0.7 % of Rate and ± 0.7 % F.S.
Fittings
½"...3" NPT or G (BSPP)
Material
Brass or 316 Stainless Steel
Maximum Temperature
194 °F
Maximum Pressure
230 PSIG
Turndown Ratio
250 to 1
Outputs
Analog, Frequency, Switching, Compact Electronics w/ Digital Displays, Batching and Totalizing Electronics
DVE - Multivariable Insertion Design Vortex Flow Meter
DVE - Multivariable Insertion Design Vortex Flow Meter
Process Connection
ANSI, DIN Wafer Flange or Threaded via Compression Fitting
Line Sizes
DN80...DN600, (3"...24")
Wetted Materials
316L St. Steel
Input Power
12-36 VDC (2 & 4 Wire), 85-240 VAC 50/60 Hz
Display
Alphanumeric 2 Line x 16 Character LCD
DVH - Multivariable Vortex Flow Meter
DVH - Multivariable Vortex Flow Meter
Fittings
1/2”...8” ANSI Flanges, 1/2"...4" ANSI Wafer
Wetted Materials
Housing/Bluff Body/Flanges - 316L St. Steel (Standard)
Input Power
12-36 VDC (2 & 4 Wire), 85-240 VAC 50/60 Hz
Optional Display
Alphanumeric 2 Line x 16 Character LCD
DVZ - Vortex Flow Meter and Switch
DVZ - Vortex Flow Meter and Switch
Range
0.13...1.2 GPM to 2.7...26 GPM
Fittings
¼"...1" NPT & G¼...G1
Fitting Material
Ni-Plated Brass, SS
Max. Pressure
145 PSIG / 290 PSIG
Max. Media Temperature
176 °F
Accuracy
± 2.5% of Full Scale
EPS - Magnetic Inductive Flow Meter for Conductive Liquids
EPS - Magnetic Inductive Flow Meter for Conductive Liquids
Measuring Range
0.5 m/s...10 m/s
Fittings
1/2” NPT, ½”…24” ANSI Flange
Lining Materials
Hard or Soft Rubber, EPDM, PTFE, or Ceramic
Max. Pressure
580 PSIG (Model Dependent)
Max. Temperature
300 °F (Model Dependent)
Accuracy
± 0.3% of Measured Value ± 0.01% (Q at 10 m/s)
HPC - High Performance Coriolis Flow Meter for Low Flows
HPC - High Performance Coriolis Flow Meter for Low Flows
Mass Flow Measuring Ranges
2...20 kg/h to 5...50 kg/h
Connections
1/2" NPT, Gyrolok, Swagelok
Accuracy (Liquid)
± 0.1% of Reading
Max. Pressure
5,800 PSI
Max. Operating Temperature
350 °F
KAH - Air Velocity Sensor
KAH - Air Velocity Sensor
Selectable Sensing Range
0 ... 2000 / 3000 / 4000 ft/min
Body/Housing Material
Polycarbonate
Media Temperature Range
-13 ...122 °F
Power Supply
24 VAC/VDC ± 20%
Signal Output
4-20 mA or 0-10 VDC
Media Humidity Range
5 ... 95 % RH (Non-condensing)
KAL - Temperature-Compensating Thermal Flow Switch for Water-Based Liquids
KAL - Temperature-Compensating Thermal Flow Switch for Water-Based Liquids
Switching Range
0.2...6.6 ft/s
Fittings
1/4"...1-1/2" NPT
Material
Brass, SS
Max. Pressure
1450 PSI
Max. Temperature
176/250 °F
Output
Relay Outputs for Flow and Temperature Monitoring
KAL-A - Thermal Flow Sensor for Water-Based Liquids
KAL-A - Thermal Flow Sensor for Water-Based Liquids
Sensing Range
0.16...6.6 ft/s (Water)
Fittings
1/2" NPT, 3/4" NPT, 1½" Tri-Clamp®
Wetted Material
304, 316-Ti SS
Max. Pressure
1450 PSIG (with NPT Connection)
Max. Temperature
176 °F
Repeatability
Approx. 1%
Output Signal
4-20 mA, 3-Wire (Non-Linear)
Optional Switch
PNP Transistor, 400 mA Max.
KAL-D - Compact Thermal Flow Switch for Water-Based Liquids
KAL-D - Compact Thermal Flow Switch for Water-Based Liquids
Switching Range
0.15...6.6 ft/sec (Water)
Fittings
¼" NPT, ½" NPT, M12 x 1, G¼, G½
Wetted Material
316-Ti SS
Maximum Pressure
580 PSIG
Max. Media Temperature
176 °F
Repeatability
± 2 %
Switch Output
PNP/NPN, N/O, N/C (Specified upon Ordering)
KAL-K - Thermal Flow Switch with LED Flow Trend Indication for Water-Based Liquids
KAL-K - Thermal Flow Switch with LED Flow Trend Indication for Water-Based Liquids
Switching Range
0.2...6.6 ft/s (Water)
Fittings
½" or 3/4" MNPT, 1½" Tri-Clamp®
Wetted Material
304 or 316-Ti Stainless Steel
Max. Pressure
1450 PSIG (with NPT Connection)
Max. Operating Temperature
250 °F
Input Power
24 VDC ± 10%, 110 VAC Optional
Output
NPN/PNP Transistor, N/O Relay Only w/110 VAC Version
KAL-L - Thermal Air Flow Switch
KAL-L - Thermal Air Flow Switch
Measuring Range
3.3...66 ft/sec (Air)
Fittings
½" NPT, Flange
Output
SPDT Relay, Max. 250 VAC / 1000 VA / 4A
Max. Pressure
120 PSIG
Max. Temperature
250 °F
Switching Accuracy
± 10% of Reading
KEC - Thermal Energy Flow Meter
KEC - Thermal Energy Flow Meter
Measuring Range
0.2...90 Nm³/h to 5...2840 Nm³/h (Air), Max. 224 Nm/s
Accuracy
±1.5 % of Reading ±0.3 % of Full Scale
Maximum Pressure
100 Bar
Maximum Temperature
180°C
Process Connection
G ½...G 2, ½"...2" NPT, DN15...80 PN40 Flange, ½"...3" ANSI Class 150 & 300
Wetted Material
1.4571 St. Steel, Glass
Output
Modbus RTU, 2x 4-20 mA, Modbus TCP, pulse, alarm
KEL - Heavy Duty Differential Pressure Flow Meters
KEL - Heavy Duty Differential Pressure Flow Meters
Measuring Range
0.1...0.5 to 400...2000 GPM
Fittings
½"...1½" NPT or BSP, 1/2"... 8 " ANSI or DIN Wafer
Body Material
Brass, Brass/Cast Iron or SS
Accuracy
±3 to ±5% FS (Depending on the Model)
Max. Temperature
150 °F to 480 °F (Depending on Model)
Max. Pressure
230 PSIG
KME - Compact Inline Flow Meter
KME - Compact Inline Flow Meter
Measuring Range
0.2...76.3 to 2.2...848 Nm3/h (Air)
Accuracy
± 3 % of Reading + 0.3 % of Full Scale
Maximum Pressure
16 Bar
Operating Temperature
-20…60 °C
Process Connection
½", ¾" & 1" BSP and NPT Threaded
Wetted Materials
Aluminum, Stainless Steel, Glass
Outputs
PNP Transistor Switch, Analog Current, Pulse
KMT - Thermal Mass Flow Meter
KMT - Thermal Mass Flow Meter
Measuring Range
0.32...63 Nm³/h to 263.4...263350 Nm³/h (Air)
Accuracy
±1.5 % of Reading +0.5 to +0.8% of Full Scale
Maximum Pressure
16 Bar
Maximum Operating Temperature
+80 °C
Process Connection
G ½...G 2 & ½...2" NPT with ball valve, R½ Threaded Version for DN65...700
Wetted Materials
Stainless Steel, Glass, Brass
Outputs
Analog Output / Switch Outputs / Pulse Outputs
KPL - Orifice Plate
KPL - Orifice Plate
Maximum Pressure
420 Bar (Class 2500 tmax +500 °C )
Maximum Temperature
500° C
Process Connection
DN 50 ... DN 600, 2" ... 24" ASME Flanged
Wetted Material
Stainless Steel, Carbon Steel, Others
MAS - Mass Flow Meter for Gases
MAS - Mass Flow Meter for Gases
Measuring Ranges
0...10 SCCM to 0...500 SLPM
Fittings
¼" NPT, ½" NPT, ¼"...½" Swagelok®
Body Material
Polyamide, Aluminum, SS
Max. Pressure
150 PSIG (Polyamide, Aluminum), 500 PSIG (SS)
Max. Media Temperature
120 °F
Accuracy
± 1.5% F.S. at 15...25°C & 5...60 PSIA
Input Power
12 VDC Standard, 24 VDC Optional
Output Signal (Linear)
0-5 VDC Standard, 4-20 mA Optional
MIK - Economical Magmeter
MIK - Economical Magmeter
Available Ranges
0.18...7.8 GPH to 9...180 GPM (Water)
Accuracy
± 2% of Full Scale
Repeatability
± 1% of Full Scale
Media Temp. Range
32...176 °F (140 °F Max. w/PVC Fittings)
Media Conductivity
Minimum 30 μS/cm (Minimum 200 μS/cm for Range Codes U0 & U1)
Maximum Pressure
145 PSIG @ 70 °F
Max. Pressure Drop
3.6 PSI @ 100% Rated Flow
Max. Viscosity
20 cSt for ranges U0...U8, 70 cSt for ranges UA...UH
Wetted Materials
PPS/SS/NBR, PPS/SS/FKM, PPS/Hastelloy®/NBR, PPS/Hastelloy®/FKM, PVDF/Hastelloy®/FFKM, PVDF/Tantalum/FFKM
MIM - All-Metal Electromagnetic Flow Meter for Conductive Liquids
MIM - All-Metal Electromagnetic Flow Meter for Conductive Liquids
Process Connection Range
1/4"...2" NPT, 1" or 2" Tri-Clamp
Connection Material
316L Stainless Steel
Maximum Pressure
230 PSIG
Maximum Temperature
284 °F
Housing Material
316L Stainless Steel
Accuracy
< ±(0.8% of Reading + 0.5% of Full Scale)
MIS - Economical Electromagnetic Flow Meter
MIS - Economical Electromagnetic Flow Meter
Measuring Range
2...277 GPM to 4.4...1,100 GPM
Max. Media Viscosity
100,000 cP
Process Connection
2", 3", or 4" ANSI Flange
Maximum Pressure
230 PSIG
Repeatability
± 0.2% of Full Scale
Protection
IP67
PIT - Insertion Magnetic Flow Meter
PIT - Insertion Magnetic Flow Meter
Pipe Diameter
150...2000 mm (6"...78")
Accuracy
± 1.5% of Reading, ± 0.5% of Span (at Reference Conditions)
Fitting
Insertion Weld Sleeve with ANSI or DIN Mounting Flange
Adjustable Span
1...10 m/s (3.3...33 Ft/Sec.)
PITe - Magnetic Inductive Flow Meter
PITe - Magnetic Inductive Flow Meter
Measuring Range
1...10 m/sec (3.28... 32.8 ft/sec)
Accuracy (>30% URV)
±1.5% of Reading
Maximum Pressure
230 PSIG to 90 °C (194 °F), 200 PSIG to 100 °C (212 °F)
Maximum Temperature
100 °C (212 °F)
Process Connection
Welding Stub and M52 x 2 Union Nut for 3" to 16" pipes
Wetted Material
Stainless Steel / PTFE, Hastelloy® Electrodes
Output
Analog with HART®, Pulse, and Status
RCD - Ultra-Rugged Differential Pressure Flow Meter
RCD - Ultra-Rugged Differential Pressure Flow Meter
Measuring Range
0.2...0.88 to 100...600 GPM (Water)
Fittings
½"...3" NPT
Body Material
Brass, 316-Ti SS
Max. Pressure
580 PSIG
Max. Temperature
176 °F / 212 °F
Accuracy
± 3 % FS
Display/Output
Analog Output, Digital Display, Switches
RCM - Direct Reading Flow Meter
RCM - Direct Reading Flow Meter
Accuracy
± 3% Full Scale
Measuring Ranges
0.3...2.0 GPH to 400...3000 GPM (Liquids) / 1.5...10 SCFH to 3000...20000 SCFM (Gases)
Fittings
¼"...3" NPT, ½"...8" Wafer
Body Material
Bronze, Monel or SS
Media Temperature
-30...212 °F (Standard)
Optional High-Temp Design
-80...350 °F
Maximum Pressure
180 PSIG (Standard)
Optional High Pressure Design
400 PSIG
TM - Universal, Special Purpose Coriolis Mass Flow Meter
TM - Universal, Special Purpose Coriolis Mass Flow Meter
Mass Flow Measuring Ranges
0.003...0.3 Lb./Min. to 220...2400 Lb./Min.
Sizes
¼"...3"
Accuracy (Mass Flow)
± 0.1% of Reading
Fittings
NPT, BSPP, SAE Thread; ANSI, DIN, JIS Flange, Others on Request
Max. Operating Temperature
Up to 500 °F (Depending on Model)
TMU - High Performance Coriolis Mass Flow Meter
TMU - High Performance Coriolis Mass Flow Meter
Mass Flow Measuring Ranges
2.2...22 Lb/Min. to 220...2200 Tons/Hr.
Line Size
¼"...10" Standard (to 16" Upon Request)
Accuracy
± 0.15% of Reading or Better
Fittings
NPT Thread, ANSI CL 150/300 Flange, Others Upon Request
Max. Pressure
580 PSIG Standard (Higher Upon Request)
Max. Operating Temperature
Up to 500 °F (Depending Upon Model)