Flow Measurement without Moving Parts Products

MAS - Mass Flowmeter for Gases
MAS - Mass Flowmeter for Gases
Measuring Ranges
0...10 SCCM to 0...500 SLPM
Fittings
¼" NPT, ½" NPT, ¼"...½" Swagelok®
Body Material
Polyamide, Aluminum, SS
Max. Pressure
150 PSIG (Polyamide, Aluminum), 500 PSIG (SS)
Max. Media Temperature
120 °F
Accuracy
± 1.5% F.S. at 15...25°C & 5...60 PSIA
Input Power
12 VDC Standard, 24 VDC Optional
Output Signal (Linear)
0-5 VDC Standard, 4-20 mA Optional
MIK - Economical Magmeter
MIK - Economical Magmeter
Available Ranges
0.18...7.8 GPH to 9...180 GPM (Water)
Accuracy
± 2% of Full Scale
Repeatability
± 1% of Full Scale
Media Temp. Range
32...176 °F (140 °F Max. w/PVC Fittings)
Media Conductivity
Minimum 30 μS/cm (Minimum 200 μS/cm for Range Codes U0 & U1)
Maximum Pressure
145 PSIG @ 70 °F
Max. Pressure Drop
3.6 PSI @ 100% Rated Flow
Max. Viscosity
20 cSt for ranges U0...U8, 70 cSt for ranges UA...UH
Wetted Materials
PPS/SS/NBR, PPS/SS/FKM, PVDF/Hastelloy®/FFKM, PVDF/Tantalum/FFKM
MIM - All-Metal Electromagnetic Flowmeter for Conductive Liquids
MIM - All-Metal Electromagnetic Flowmeter for Conductive Liquids
Process Connection Range
1/4"...2" NPT, 1" or 2" Tri-Clamp
Connection Material
316L Stainless Steel
Maximum Pressure
230 PSIG
Maximum Temperature
284 °F
Housing Material
316L Stainless Steel
Accuracy
< ±(0.8% of Reading + 0.5% of Full Scale)
MIS - Economical Electromagnetic Flowmeter
MIS - Economical Electromagnetic Flowmeter
Measuring Range
2.65...700 GPM to 4.4...1,100 GPM
Max. Media Viscosity
70 mm2/s
Process Connection
3" or 4" ANSI Flange
Maximum Pressure
230 PSIG
Repeatability
± 0.2% of Full Scale
Protection
IP67
PIT - Insertion Magnetic Flowmeter
PIT - Insertion Magnetic Flowmeter
Pipe Diameter
150...2000 mm (6"...78")
Accuracy
± 1.5% of Reading, ± 0.5% of Span (at Reference Conditions)
Fitting
Insertion Weld Sleeve with ANSI or DIN Mounting Flange
Adjustable Span
1...10 m/s (3.3...33 Ft/Sec.)
PITe - Magnetic Inductive Flowmeter
PITe - Magnetic Inductive Flowmeter
Measuring Range
1...10 m/sec (3.28... 32.8 ft/sec)
Accuracy (>30% URV)
±1.5% of Reading
Maximum Pressure
230 PSIG to 90 °C (194 °F), 200 PSIG to 100 °C (212 °F)
Maximum Temperature
100 °C (212 °F)
Process Connection
Welding Stub and M52 x 2 Union Nut for 3" to 16" pipes
Wetted Material
Stainless Steel / PTFE, Hastelloy® Electrodes
Output
Analog with HART®, Pulse, and Status
RCD - Ultra-Rugged Differential Pressure Flowmeter
RCD - Ultra-Rugged Differential Pressure Flowmeter
Measuring Range
0.2...0.88 to 100...600 GPM (Water)
Fittings
½"...3" NPT
Body Material
Brass, 316-Ti SS
Max. Pressure
580 PSIG
Max. Temperature
176 °F / 212 °F
Accuracy
± 3 % FS
Display/Output
Analog Output, Digital Display, Switches
RCM - Direct Reading Flowmeter
RCM - Direct Reading Flowmeter
Accuracy
± 3% Full Scale
Measuring Ranges
0.3...2.0 GPH to 400...3000 GPM (Liquids) / 1.5...10 SCFH to 3000...20000 SCFM (Gases)
Fittings
¼"...3" NPT, ½"...8" Wafer
Body Material
Bronze, Monel or SS
Media Temperature
-30...212 °F (Standard)
Optional High-Temp Design
-80...350 °F
Maximum Pressure
180 PSIG (Standard)
Optional High Pressure Design
400 PSIG
TM - Universal, Special Purpose Coriolis Mass Flowmeter
TM - Universal, Special Purpose Coriolis Mass Flowmeter
Mass Flow Measuring Ranges
0.003...0.3 Lb./Min. to 220...2400 Lb./Min.
Sizes
¼"...3"
Accuracy (Mass Flow)
± 0.1% of Reading
Fittings
NPT, BSPP, SAE Thread; ANSI, DIN, JIS Flange, Others on Request
Max. Operating Temperature
Up to 500 °F (Depending on Model)