Product Description

The KOBOLD flow meters and switches, models UVR and UTR for liquids and air operate on the variable-area (suspended float) principle: that is, the installation position is vertical and the direction of flow is from bottom to top.

These rotameters have been designed as simple, thus economical measuring systems. The float for the UVR and the UTR is made of PVC, PTFE or stainless steel, depending upon media and range with the indication point at the top of the float. The flow meter is available with or without a needle valve.

UVR - UTR - Glass Tube Variable Area Flow Meter w/Needle Valve

Product Specifications

Measuring Range
10…100 to 200…2000 L/h (Water)
Accuracy
4 acc. to VDI/VDE 3513
Maximum Pressure
10 Bar
Maximum Temperature
100°C
Process Connection
G 3/8, G ½, 3/8" NPT, ½" NPT Female Thread
Wetted Material
POM-C, Stainless Steel 1.4301, 1.4404
Output
Optional Switch Contacts

Product Features

Variable Area Design
Low Pressure Loss
Glass Tube Allows Direct Flow Observation