What Is the KSR/SVN Low Volume Flow Switch?
The KOBOLD KSR/SVN is a micro flow switch that monitors very small flows of liquids or gases using the float-type, variable area principle. Its switch point is factory set, and it is available with a reed contact (KSR) or an inductive proximity switch (SVN). Switching ranges cover 0.03 to 4.0 GPH of water and 0.1 to 13 SCFH of air.
Provided that the flow rate is above a preselected minimum, the float is raised from its seat and travels the full distance to its upper stop. The set point is set to the value specified by the customer, for either an increasing or a decreasing flow rate.
KSR vs. SVN: Reed Contact or Proximity Switch
The two models differ in how the float position is detected. The KSR contains a magnet within its float, which activates an electrically isolated reed switch. The SVN uses an inductive proximity switch that transmits a signal to a suitable power supply/relay module, such as the KOBOLD KFA or KFD series, triggering a user specified signaling or switching sequence.
- SVN-1201: proximity switch, 10-30 VDC, 3-wire, NPN, N/O contact
- KSR-1200: reed contact, N/O, max. 24 V / 0.1 A / 1 W
- KSR-1201: reed contact, SPDT, max. 100 V / 0.5 A / 5 W
As long as the maximum switching capacity of the reed switch is not exceeded, the KSR requires no supplemental relay to provide a triggering function. If additional switching capacity is required, KOBOLD can supply an appropriate isolation relay to protect the flow switch contacts from overload damage.
KSR/SVN Specifications: Flow Range, Pressure, and Materials
The KSR/SVN is rated for a maximum pressure of 230 PSIG (16 bar) and a maximum temperature of 160 °F (70 °C). Wetted parts are 303 stainless steel, borosilicate glass, and FKM, inside an anodized aluminum housing. Process connections are 1/4" NPT or G 1/4 threads, arranged vertically for inline mounting.
- Switching range, water (SVN): 0.03 to 4.0 GPH (2 to 250 cm³/min)
- Switching range, water (KSR): 0.03 to 2.5 GPH (2 to 160 cm³/min)
- Switching range, air: 0.1 to 13 SCFH at STP (50 to 6,000 Ncm³/min)
- Overall height: 4.33 in (110 mm)
- Overall width including switch: 4.02 in (102 mm) for the SVN, 3.35 in (85 mm) for the KSR
- Wrench flats: 0.87 in (22 mm)
How to Install the KSR/SVN Flow Switch
The KSR/SVN must be fitted vertically with the media flowing from bottom to top. Piping should be rigidly supported with pipe clamps at the inlet and outlet of the switch, and aligned with the fittings so that no piping-induced stress is exerted on the device. Such stress can result in damage during system operation.
- Remove all packing materials and transport retainers before installation.
- Make sure the maximum operating pressure and temperature of the device are not exceeded.
- Protect the measuring tube from external damage.
- Avoid pressure surges in the measuring tube, such as those arising from fast start-up or shut-off of flow, or from pulsating flow.
- If possible, check the threaded connections for leakage immediately after the mechanical installation.
- Make sure the electrical supply lines are de-energized when connecting the device.
Maintenance and Cleaning
If the medium is not dirty, KSR/SVN flow switches are essentially maintenance-free. Any lime or dirt deposits on the housing or the internal parts should be removed regularly. For cleaning, the unit is de-energized, unscrewed from the line, disassembled by removing the stud screws, and cleaned in a cleaning bath or an ultrasonic bath.
When reassembling the flow switch, be sure that the gaskets are seated properly.
How to Order the KSR/SVN
An order specifies the model (SVN-1201, KSR-1200, or KSR-1201), the media (W for water or L for air), the connection (N08 for 1/4" NPT or R08 for G 1/4), and the set point, stated in writing. For air models, the operating pressure and temperature are also included with the order.
Example: SVN-1201 W N08 with a set point of 3 GPH, increasing flow rate.
Common Questions about KSR/SVN - Low Volume Flow Switch for Liquids or Gases
Both versions work on the suspended float principle and are suited for liquids and gases. When flow exceeds the preselected minimum, the float lifts off its seat and rises to the upper stop. In the KSR, a magnet in the float actuates a reed contact; in the SVN, an inductive proximity sensor provides the signal.
For water, the SVN can be supplied with a switch point from 0.03 up to 4.0 GPH (2 to 250 cm³/min), while the KSR covers 0.03 up to 2.5 GPH (2 to 160 cm³/min). For air, the range is 0.1 up to 13 SCFH at STP. The exact switch point is fixed at the factory for each order.
Pressure up to 230 PSIG (16 bar) and temperature up to 160 °F (70 °C) are the limits for both the KSR and the SVN. Before installation, confirm that conditions in the line stay within these limits, and avoid pressure surges caused by fast start-up, fast shut-off, or pulsating flow.
Not in every case. The KSR-1200 normally open contact handles up to 24 V, 0.1 A, 1 W, and the KSR-1201 SPDT contact handles up to 100 V, 0.5 A, 5 W. These values must not be exceeded, even for a short time. For higher switching capacities, a contact protection relay such as the KOBOLD MSR is recommended.
The SVN-1201 is a 3-wire DC device with an NPN, normally open output, supplied with 10-30 VDC. Its signal is wired to a relay or power supply unit; the KFA and KFD series are examples. The electrical values specified for the proximity switch must not be exceeded.
The parts that touch the media are FKM, borosilicate glass, and 303 stainless steel. The housing is anodized aluminum. Threaded connections are offered in two versions, 1/4" NPT (order code N08) and G 1/4 (order code R08), and the unit stands 4.33 in (110 mm) tall in both the KSR and SVN versions.
No. The switch is built for vertical installation only, and flow has to enter at the bottom connection and leave at the top. Support the pipework with clamps on both sides of the device and keep it aligned so the fittings are not stressed, since stress from the piping can damage the switch.
The customer specifies the switch point when ordering, and KOBOLD sets it at the factory. The order gives the flow value and whether the switch should act on rising or falling flow, for example 3 GPH increasing or 5 SCFH decreasing. Air versions also need the operating pressure and temperature stated.
First de-energize the electrical supply lines, then unscrew the unit from the pipe. Taking out the stud screws lets the switch come apart so the parts can go into a cleaning bath or ultrasonic bath. On reassembly, check that the gaskets sit correctly. With clean media, the switch needs very little maintenance.
Product Specifications
Switching Range
Water: 0.03...4.0 GPH (SVN), 0.03...2.5 GPH (KSR); Air: 0.1...13 SCFH
Fittings
¼" NPT Thread, G¼
Wetted Materials
303 SS, Borosilicate Glass, FKM
Max. Media Temperature
160 °F (70 °C)
Contact
Proximity Switch or Reed Contact
Media Categories
Liquid or Gas
Product Features
Control of Very Small Flows
Proximity Switch or Reed Contact
Vertical Connections for Inline Mounting
BABA (Build America, Buy America) compliant models available
Documents
Software Downloads
There are no downloads to display at this time. If you think this is incorrect, please contact us and let us know the issue you are having.
Videos
There are no videos to display at this time. If you think this is incorrect, please contact us and let us know the issue you are having.
Accessories
There are no accessories to display at this time. If you think this is incorrect, please contact us and let us know the issue you are having.