MS Magnetic Level Switches for Liquid Level Monitoring and Control
The MS is a side-mounted magnetic float level switch that monitors and controls liquid levels in vessels. A ring magnet in the float actuates hermetically sealed contacts without touching them. Up to 3 switch points are available, with ratings up to 1450 psi (100 bar) and 302°F (150°C) depending on the float model.
Each switch is manufactured to customer specification, including the guide tube length, the number and function of contacts, and the switch point positions.
How the MS Magnetic Float Switch Works
A hermetically sealed reed contact sits inside the guide tube. The float slides along the tube as the liquid level rises and falls, and the magnetic field of its ring magnet switches the contact in a noncontacting fashion. The float is the only moving part.
MS Float Models, Materials, and Pressure and Temperature Ratings
Four float models set the operating limits. Pressure ratings at 68°F (20°C) run from 43.5 psi (3 bar) to 1450 psi (100 bar), maximum temperatures from 131°F (55°C) to 302°F (150°C), and minimum liquid densities from 0.5 to 0.9 kg/dm³.
- MS05: hollow PP cylinder float, 1.65 in (42 mm) diameter. Rated 43.5 psi (3 bar) and 176°F (80°C) for densities above 0.5 kg/dm³.
- MS06: solid PP cylinder float, 1.57 in (40 mm) diameter, for high-pressure applications. Rated 1450 psi (100 bar) and 194°F (90°C) for densities above 0.9 kg/dm³.
- MS07: hollow PVC-U cylinder float, 1.65 in (42 mm) diameter, on a PVC guide tube. Rated 43.5 psi (3 bar) and 131°F (55°C) for densities above 0.65 kg/dm³.
- MS10: hollow stainless steel 1.4404 ball float, 2.05 in (52 mm) diameter. Rated 435 psi (30 bar) and 302°F (150°C) for densities above 0.6 kg/dm³.
The MS05, MS06, and MS10 use a brass or stainless steel 1.4404 guide tube up to 13.1 ft (4 m) long. The MS07 guide tube is PVC, up to 6.56 ft (2 m) long.
Switch Points, Contact Functions, and Electrical Ratings
The MS provides up to 3 switch points. Each contact is available as normally open (N/O), normally closed (N/C), or changeover (SPDT) and is rated 230 V AC/DC, 1 A, 60 VA. Contact state is referenced to an empty tank. Hysteresis is 0.2 in (5 mm), and the protection type is IP65.
The electrical connection is a 3.28 ft (1 m) PVC or silicone cable, a cable of special length and type, or a connection housing. PVC cable is limited to 158°F (70°C), or 131°F (55°C) on the MS07.
Contact protection relays are recommended with the sealed contacts. The rated values are absolute maximums for resistive loads, so inductive, capacitive, and lamp loads call for contact protection relays or suppressor circuits. Models without an earth conductor must be used only with safety extra low voltage or external earthing.
How to Install the MS Level Switch
The MS installs through the side of the vessel, and the guide tube must not deviate more than ±30° from vertical. The float must be able to move freely, with allowance for the distance from the side walls. The switch should not be installed near strong magnetic fields, which can impair its function.
The guide tube must not be bent or exposed to hard impacts, which can damage the reed contacts inside. The adjustment rings and anchor clamps must not be readjusted. If the float does not fit through the process connection, it is removed before mounting.
MS Process Connections and Connection Heads
The process connection on the guide tube is a G⅜ thread. Connection heads provide G1½, G2, 1½" NPT, or 2" NPT threads, or flanges to DIN EN 1092-1 PN16 (DN40 to DN125) and ANSI B16.5 150 lb RF (1½" to 4"). The process connection size must match the float size.
Threaded connection heads have an aluminum housing rated to 194°F (90°C) or an ABS housing rated to 131°F (55°C). Flanged heads combine a stainless steel 1.4404 flange with an aluminum housing. The electrical connection on connection heads is M16 x 1.5.
ATEX Versions for Hazardous Areas
ATEX-certified versions of the MS carry the marking II 1 GD Ex ia IIC T6 Ga / Ex ia IIIC T85°C Da for ambient temperatures from -4°F to 140°F (-20°C to +60°C), with Ui of 40 V. They can be installed in zone 0, 1, 20, or 21, or in an unclassified area.
Installation in hazardous areas must be carried out by trained personnel.
Suitable Liquids and Maintenance
The MS is used exclusively for level control and monitoring of liquids. The liquid should not contain suspended solids or tend to crystallize, and the construction materials of the switch must have sufficient chemical resistance to it. In liquids that can cause deposits, the float and measuring tube are cleaned at regular intervals.
Common Questions about MS - Magnetic Level Switches
It is a float switch for liquids. A float carrying a magnet rides up and down a guide tube as the level in the tank changes, and each time it passes a sealed reed contact inside that tube, the contact changes state. Nothing except the float moves during switching.
Limits depend on the float. The MS06, with its solid PP float, has the highest pressure rating at 1450 psi (100 bar). The MS10, with its stainless steel ball float, has the highest temperature rating at 302°F (150°C). The MS05 and MS07 are both limited to 43.5 psi (3 bar).
The liquid must be denser than the minimum for the chosen float: more than 0.5 kg/dm³ with the MS05, 0.6 kg/dm³ with the MS10, 0.65 kg/dm³ with the MS07, and 0.9 kg/dm³ with the MS06. Published switch point spacing is based on a density of 1.0 kg/dm³.
A single unit can carry as many as three contacts, identified as L1, L2, and L3 counting from the top. With an MS05, MS07, or MS10, two of those contacts can share the same float. On an MS06, every switch point needs a float of its own.
Minimum L1 to L2 spacing is 1.77 in (45 mm), or 2.76 in (70 mm) on the MS06. L2 and L3 need 2.13 in (54 mm) on the MS05 and MS07, 2.60 in (66 mm) on the MS10, and 2.76 in (70 mm) on the MS06. Tolerance is ±0.12 in (±3 mm); ±0.28 in (±7 mm) on the MS06.
All three contact versions share one rating: 230 V AC/DC, 1 A, and 60 VA, and ATEX units have a Ui value of 40 V. These figures apply to ohmic loads and may not be exceeded even briefly. Inductive loads need protection, such as an RC suppressor on AC or a diode on DC.
Mount it so the tube sits within 30° of vertical and the float can travel without touching the tank wall. Keep it away from strong magnetic fields, and never bend or strike the tube. A float too large for the process connection is taken off first, with its orientation mark noted so it goes back on the same way.
Cable conductors follow DIN 47100 color coding: white, brown, green, yellow, grey, pink, blue, red, and black match terminals 1 through 9 in a connection head. An N/O or N/C contact takes two conductors and a changeover contact takes three. Special cables are identified by number instead of color.
Yes. Choosing E in the ATEX position of the model code selects the certified version, while 0 selects a unit without certification. The MS...E series is covered by certificate LOM 06ATEX2054 X for gas or dust explosion hazard environments, category 1G/D. Units supplied without a connection head need an enclosure of at least IP20.
Cleaning is the only routine task. Where the liquid tends to leave deposits, clean the float and the tube it rides on at regular intervals; no other maintenance jobs are required. For storage, protect the switch from humidity and dust and keep it between 23°F and 131°F (-5°C and +55°C).
Product Specifications
Connection
G ⅜, G 1½, G 2, 1½" NPT, 2" NPT male, DIN and ANSI Flanges, Special Connections
Material
Stainless Steel, Brass, PVC-U, PP
Connection Heads
Aluminium, ABS
Product Features
Long electrical service life due to sealed contacts
High-degree of operational reliability with air gap between measuring tube and floats
Several levels can be monitored with one float
Open/close function or changeover contact available