NCB Magnetic Float Switch with NBR Float
The NCB is a general purpose magnetic float level switch for liquids that uses a hermetically sealed reed contact actuated by a magnet in its NBR float. As the float rises and falls with the liquid level, the magnetic field causes the SPST switch inside the stem to open or close at a single point.
The NCB is available in top-mount versions with a 316 stainless steel or brass stem and in a side-mount version with a 316 stainless steel stem. Every model is rated to 150 PSIG (10.3 bar) and is designed for media with a minimum specific gravity of 0.55.
NCB Float Switch Models and Float Sizes
The NCB series includes six top-mount models in small, intermediate, and large float sizes, each offered with a 316 stainless steel or brass stem, plus one side-mount model, the NCB-5171, with a 316 stainless steel stem and a 90° bend. All models use an NBR float and an SPST switch.
- Small float, NCB-1054 (316 SS stem) and NCB-1064 (brass stem): 1.00" (25 mm) diameter float, 1/8" NPT fitting, 22 AWG x 24" (610 mm) lead, 20 VA switch.
- Intermediate float, NCB-1084 (316 SS stem) and NCB-1094 (brass stem): 1.19" (30 mm) diameter float with compact, narrow displacement, 1/8" NPT fitting, 18 AWG x 24" (610 mm) lead, 100 VA switch.
- Large float, NCB-5124 (316 SS stem) and NCB-5134 (brass stem): 1.88" (48 mm) diameter float, 1/4" NPT fitting, 18 AWG x 24" (610 mm) lead, 100 VA switch. It provides maximum displacement and is built for industrial service.
- Side mount, NCB-5171 (316 SS stem): 1.00" (25 mm) diameter float, PF 1/8" (3/8"-24) fitting, 22 AWG x 11" (279 mm) lead, 20 VA switch. The bend allows mounting where access to the tank top or bottom is restricted.
Pressure, Temperature, and Specific Gravity Ratings
All NCB models are rated for a maximum pressure of 150 PSIG (10.3 bar). The operating temperature range is -40 to 230°F (-40 to 110°C) in oil and -40 to 180°F (-40 to 80°C) in water. The minimum specific gravity of the media is 0.55. Wetted materials are NBR, brass, and 316 stainless steel.
Operation outside these limits will cause damage to the unit and possible injury to personnel.
Mounting and Normally Open or Normally Closed Switch Logic
Top-mount NCB switches install at the top or bottom of the tank with the float positioned vertically or at up to a 30° inclination. The switch logic is field selectable: the standard normally open (N/O) operation changes to normally closed (N/C) by removing the retaining ring, inverting the float, and reinstalling the ring.
The float differential between the actuating and deactuating points is approximately 1/8" (3.2 mm). The side-mount NCB-5171 installs through a drilled and deburred 13/32" (10.3 mm) hole with the float positioned vertically or at up to a 30° inclination, and its logic can also be changed by inverting the unit. Use a proper sealant, never overtighten the switch in its fitting, and check for leaks before system start-up.
Electrical Ratings and Contact Protection
NCB reed switches are SPST contacts intended for pilot duty service. Small and side-mount models carry a 20 VA contact rating, and intermediate and large models carry a 100 VA rating. The 100 VA switch is rated for resistive loads up to 240 VAC/VDC at 1.0 A AC and 0.4 A DC.
The reed switch is not designed to directly switch solenoid valves, motors, or other high current devices. Common accepted practice is an interface relay rated to handle the required load. Contact protection is required when switching inductive loads, and a contact protection relay should be considered to protect the switch from overload. The MSR contact protection and latching relay is available as an accessory.
Liquid Compatibility and Hazardous Applications
The NCB must be chemically compatible with the application liquid. It is not recommended for viscous, sticky, or coating-type liquids, because float movement will be impeded, and some solutions or mixtures may cause the float to become inoperative if allowed to dry. The NCB is not an explosion-proof design.
The switch can be made intrinsically safe for hazardous applications by the use of an intrinsically safe (I.S.) barrier. The switch wiring is liquid resistant when installed properly but is not designed to be immersed, so the fitting should be mounted and sealed so that the wiring does not normally come into contact with fluid.
Common Questions about NCB - Magnetic Float Switches with NBR Float
The float carries a magnet and moves along the stem as the level changes. Its field acts on the reed contact sealed within the stem, and that contact opens or closes. On a top-mounted switch in an empty tank, a normally open contact closes on liquid rise, and a normally closed contact opens on liquid rise.
Every NCB version has a 150 PSIG (10.3 bar) pressure limit. In oil, the switch works between -40 and 230°F (-40 and 110°C). In water, the upper limit is 180°F (80°C). Running it beyond these ratings can damage the switch.
No. Its reed contact handles only very small loads. The usual approach is to add an interface relay sized for the electrical load: the low current signal from the float switch energizes the relay coil, and the relay contacts then carry the larger load current.
Voltage spikes can be generated when a relay coil is activated, even if the coil current is well below the reed switch rating. For an AC source, install a varistor (MOV) or resistor/capacitor filter across the relay coil. For a DC source, place a general purpose diode (1N4004) across the coil, cathode toward the more positive side.
Take the retaining ring off the stem, turn the float over, and put the ring back on. This reverses the contact action in the field. On the side-mount NCB-5171, the action is reversed either the same way or by turning the entire unit over.
Yes. The NCB-5171 has a stem bent at 90° for tanks with limited top or bottom access. It uses a PF 1/8" (3/8"-24) fitting and mounts through a 13/32" (10.3 mm) hole that has been drilled and deburred. Its float should sit vertically or within 30° of vertical.
No. It should not be installed anywhere an explosion-proof design is required. For hazardous applications, adding an I.S. barrier can make it intrinsically safe. In critical applications, KOBOLD recommends a fail-safe system with redundant backup systems and alarms in addition to the primary system, to allow for possible switch or power failure.
Check switch operation with an ohmmeter only, never with a light. Installation and maintenance should be handled by properly trained personnel, with supply voltage and current kept within the recommended limits. Electrical wiring should be performed in accordance with all applicable national, state, and local codes.
Product Specifications
Fittings
1/8" NPT, 1/4" NPT, PF 1/8" (3/8"-24)
Wetted Materials
NBR, Brass, 316 St. Steel
Max. Temperature
230°F (110 °C) (in Oil), 180°F (80 °C) (in Water)
Specific Gravity
0.55 S.G. minimum
Product Features
Reliable Performance, Long-Life Expectancy
Highly Resistant to Shock and Vibration
Field Selectable - Normally Open (N/O) or Normally Closed (N/C)
Documents
Software Downloads
There are no downloads to display at this time. If you think this is incorrect, please contact us and let us know the issue you are having.
Videos