NCS Stainless Steel Magnetic Float Level Switch for Liquids
The KOBOLD NCS is a magnetic float level switch for liquids with a 316 stainless steel stem and float. A magnet in the float actuates a hermetically sealed reed contact inside the stem, giving single-point level detection at pressures up to 400 PSIG (27.6 bar) and temperatures up to 300 °F (150 °C).
The all stainless steel construction is compatible with corrosive media, withstands high temperatures and pressures, and is resistant to shock and vibration. The NCS is available in small and large sizes, in standard and waterproof versions, and in a bent-stem version for side mounting.
How Does the NCS Magnetic Float Switch Work?
As the float rises and falls with the liquid level, the magnetic field of the permanent magnet in the float causes the SPST reed switch inside the stem to open or close. The float differential between the actuating and deactuating points is approximately 1/8" (3.2 mm).
Every model is field selectable for normally open or normally closed operation. Switch logic is changed by removing the retaining ring, inverting the float, and reinstalling the ring. In a tank-top mount, a contact that is normally open when dry closes on liquid rise, and a contact that is normally closed when dry opens on liquid rise.
NCS Models, Pressure and Temperature Ratings
The NCS is offered in five models. The small NCS-1074 is rated to 142 PSIG (9.8 bar) from -4 to 248 °F (-20 to 120 °C). The large NCS-1104, NCS-7201, and NCS-7202 are rated to 400 PSIG (27.6 bar) and the side-mount NCS-5161 to 275 PSIG (19.0 bar), both from -40 to 300 °F (-40 to 150 °C).
- NCS-1074 (small, standard): 1.1" (28 mm) diameter float, 1/8" NPT fitting, 22 AWG x 24" (610 mm) lead, minimum liquid specific gravity 0.77, 20 VA SPST switch.
- NCS-1104 (large, standard): 2.15" (54.6 mm) diameter float, 1/4" NPT fitting, 18 AWG x 24" (610 mm) lead, minimum liquid specific gravity 0.65, 100 VA SPST switch.
- NCS-7201 (large, waterproof): 1/4" NPT fitting, 18 AWG x 120" (3.05 m) lead, minimum liquid specific gravity 0.65, 20 VA SPST switch.
- NCS-7202 (large, waterproof): 1/2"-13 UNF fitting, 18 AWG x 120" (3.05 m) lead, minimum liquid specific gravity 0.65, 20 VA SPST switch.
- NCS-5161 (side mount): 90° bent stem, PF 1/8" (3/8"-24) fitting, 22 AWG x 11" (279 mm) lead, minimum liquid specific gravity 0.77, 20 VA SPST switch.
How Is the NCS Float Switch Mounted and Installed?
NCS switches mount in the tank top or bottom with the float positioned vertically, and operate with up to a 30° tilt from vertical. Where access to the tank top or bottom is restricted, the NCS-5161 uses a 90° bend for side mounting through a 13/32" (10.3 mm) diameter hole.
- Use a proper sealant with all installations, never overtighten the switch within its fittings, and check for leaks before system start-up.
- The switch wiring is liquid resistant when installed properly, but it is not designed to be immersed. Mount and seal the fitting so the wiring does not normally come into contact with fluid.
- On the NCS-5161, switch logic can also be changed by inverting the unit.
Electrical Ratings and Contact Protection
The NCS uses an SPST reed switch rated 20 VA or 100 VA, depending on the model, with a maximum voltage of 240 VAC/VDC. Reed switches are sensing contacts for pilot duty service and are not designed to directly switch solenoid valves, motors, or other high current devices.
For resistive loads, the 100 VA switch is rated to a maximum of 1.0 A AC or 0.4 A DC.
Common practice is to use an interface relay rated for the required load, so the low current signal from the reed switch energizes the relay coil. Contact protection is required when switching inductive loads. With an AC source, install a varistor (MOV) or a resistor/capacitor filter across the relay coil. With a DC source, place a general purpose diode (1N4004) across the relay coil, with the cathode connected to the more positive side.
A contact protection relay should be considered to protect the switch from overload. The MSR contact protection and latching relay is available as an accessory.
Hazardous Application Use
NCS switches can be made intrinsically safe for hazardous applications by the use of intrinsic safety (I.S.) barriers. The NCS models listed on this page are not an explosion-proof design and should not be used in applications where an explosion-proof design is required. Design a fail-safe system that accommodates the possibility of switch or power failure.
Common Questions about NCS - Magnetic Float Switches for Liquids
The NCS is a single-point level switch. When the liquid level moves the float along the stem, the magnet inside the float changes the state of the sealed reed contact, opening or closing the SPST circuit. The float differential is about 1/8" (3.2 mm), and contact logic can be set in the field.
Ratings vary by model. Large vertical models handle a maximum of 400 PSIG (27.6 bar); the side-mount model handles 275 PSIG (19.0 bar). Both reach 300 °F (150 °C). The small model handles 142 PSIG (9.8 bar) and 248 °F (120 °C). Minimum temperature is -40 °F (-40 °C), or -4 °F (-20 °C) for the small model.
Models NCS-1104, NCS-7201, and NCS-7202 need a liquid with a specific gravity of at least 0.65. The NCS-1074 and the side-mount NCS-5161 need at least 0.77. Those two models have a float 1.1" (28 mm) in diameter, compared with 2.15" (54.6 mm) on the three large-float models.
Yes, in the field. On vertical models, take off the retaining ring, turn the float over, and put the ring back on. The side-mount NCS-5161 can be changed the same way or by inverting the whole unit. Mounted from the tank top, a contact that is open when dry closes as the liquid rises.
Fittings vary by model. The NCS-1074 has a 1/8" NPT fitting, and the NCS-1104 and NCS-7201 have a 1/4" NPT fitting. The NCS-7202 has a 1/2"-13 UNF fitting, and the side-mount NCS-5161 has a PF 1/8" (3/8"-24) fitting. The hex is 1/2" on the NCS-1074 and 5/8" on the large models.
Yes. Vertical models install at the top or bottom of the tank and operate at an inclination of up to 30°. For side entry, the NCS-5161 has a 90° bend and installs through a drilled and deburred 13/32" (10.3 mm) hole, with its float vertical or within 30° of vertical.
The NCS-1104 has a 100 VA SPST reed switch. The NCS-1074, NCS-7201, NCS-7202, and NCS-5161 have a 20 VA SPST reed switch. Maximum voltage is 240 VAC/VDC for both ratings. Inductive loads call for contact protection, and the voltage and current supplied to the switch must stay within the rated limits.
No. The reed contact is a sensing device that can only switch very small loads. Connecting it directly to a motor, solenoid valve, or other high current device can burn out the reed switch. Use an interface relay sized for the load, and test the reed switch with an ohmmeter, not a light.
Liquids that are viscous, sticky, or prone to coating are not recommended because they impede the float. Some solutions or mixtures can also leave the float inoperative if they are allowed to dry. Before installation, make sure the 316 stainless steel switch is chemically compatible with the liquids in the application.
No. The NCS-1074, NCS-1104, NCS-7201, NCS-7202, and NCS-5161 are not explosion-proof and should not be installed in service that calls for an explosion-proof design. For hazardous applications, the switch can be made intrinsically safe with I.S. barriers. In critical applications, KOBOLD recommends redundant backup systems and alarms in addition to the primary system.
Product Specifications
Fittings
1/8" NPT, 1/4" NPT, 1/2"-13 UNF, PF 1/8" (3/8"-24)
Max. Temperature
300 °F (150 °C)
Product Features
Small, Compact Size with Small Displacement
Highly Reliable, Yet Inexpensive
All Stainless Steel Construction
Excellent Chemical Resistance