NDT Static Pressure Level Switch for Open and Vented Tanks
The KOBOLD NDT is a static pressure level switch that monitors liquid levels in open or vented tanks without the liquid contacting the sensing mechanism. A pressure switch mounted above the tank senses the air trapped in a user-supplied pipe and changes state when the liquid rises approximately 4 inches (10.2 cm) beyond the pipe end.
The NDT functions with coating, dirty, and viscous liquids, and it is designed to be a reliable and economical choice for level monitoring. Two versions are available: the NDT-2020 with an R½ (½" BSPT) female threaded connection, and the NDT-2080 with a hose and clamp fitting for 1¼" OD pipe.
How the NDT Static Pressure Level Switch Works
The NDT uses the static pressure principle. When rising liquid reaches the bottom edge of the user-supplied pipe, it seals the pipe end and confines a volume of air inside. As the level continues to rise, the liquid compresses that air pocket, and the pressure switch connected to it changes state.
The pressure in the air pocket corresponds to the height of the media above the pipe end. The switch is factory adjusted to trip at 4 inches of water column, which places the rising switchpoint approximately 4 inches (10.2 cm) beyond the end of the pipe. On a falling level, the switch resets at approximately 3 inches (7.6 cm) beyond the pipe end. Because the pressure switch is mounted above the media level, switching takes place without the media contacting the sensing mechanism.
Setting the Switchpoint with the User-Supplied Pipe
The NDT switchpoint is set by the length of the pipe attached to the switch. The pipe is cut so that it extends into the tank 4 inches (10.2 cm) farther than the desired setpoint. For a switchpoint 12 inches (30.5 cm) below the top of the tank, the pipe extends 16 inches (40.6 cm) into the tank.
Since the pipe is user-supplied, compatibility with chemical media is readily achieved, and the arrangement is designed to allow mounting flexibility.
NDT Specifications and Materials
The NDT has an SPDT mechanical switch rated for a maximum of 250 VAC at 6 A resistive load, a media temperature range of 15 to 185 °F (-9 to 85 °C), and NEMA 4 protection. The only part directly exposed to the liquid is the user-supplied pipe.
- Media: compatible, free-flowing liquids
- Wetted parts directly exposed to liquid: user-supplied pipe
- Parts exposed to vapors: NBR and polyamide (plus zinc-plated steel on the hose and clamp version)
- Sensor housing: black polyamide
- Fitting: R½ female thread, or hose with clamp for 1" SCH 40 (1¼" OD) pipe
- Switchpoint, rising level: approximately 4 inches (10.2 cm) beyond the end of the user-supplied pipe
- Switchpoint, falling level: approximately 3 inches (7.6 cm) beyond the end of the user-supplied pipe
- Switch hysteresis: approximately 20%
- Switch error: ±10%
- Electrical terminals: 1 = common, 2 = normally closed, 3 = normally open
- Housing dimensions: 3 inches (76 mm) in diameter and 4.25 inches (108 mm) high, with a PG 16 cable gland
Installing and Maintaining the NDT Level Switch
The NDT must be mounted above the top of the tank so that the fluid cannot contact the switch internals. Both the level switch and the pipe must be rigidly supported to prevent damage to the pipe fitting. If fluid floods the switch internals, the setpoint may be permanently altered or the switch may be damaged.
- On the threaded version, apply a thread sealant such as PTFE tape to the threads for an air-tight fit.
- After the electrical connections are made, tightly secure the housing lid and the cable gland to maintain the watertight integrity of the unit.
- Do not exceed the maximum tolerances of temperature, pressure, or electrical loading.
- Double check all electrical connections before placing the unit into service. Miswired connections can cause immediate and permanent damage to the instrument.
Because the NDT is designed to function without contacting the media, it requires virtually no maintenance. An occasional inspection of the electrical connections for tightness and corrosion is recommended. If the process media tends to coat tanks and piping, the pressure pipe should be removed and cleaned periodically.
Common Questions about NDT - Static Pressure Level Switch
A static pressure level switch detects liquid level by sensing the pressure that the liquid exerts on a pocket of air. In the NDT, that air is confined in a pipe that reaches down into the tank, and a differential pressure switch responds once the liquid height above the pipe's lower edge reaches the factory setting.
The NDT is intended for open tanks and vented tanks holding compatible, free-flowing liquids. It also operates with liquids that are dirty, viscous, or prone to coating. Media never reaches the sensing mechanism, since the pressure switch sits above the liquid and only the pipe is exposed to it.
With the level rising, the contact changes state roughly 4 inches (10.2 cm) past the lower end of the sensing pipe. With the level falling, it resets roughly 3 inches (7.6 cm) past that same point. Switch error is ±10%, and switch hysteresis is about 20%.
Take the distance from the tank top down to the level where switching is wanted, then add 4 inches (10.2 cm). A setpoint located 12 inches (30.5 cm) down, for example, calls for 16 inches (40.6 cm) of pipe inside the tank.
Two models cover the pipe connection. The NDT-2020 accepts threaded pipe through a female R½ (½" BSPT) thread. The NDT-2080 uses a hose secured with clamps and fits pipe with a 1¼" outside diameter, which corresponds to 1" SCH 40 pipe. In both cases the user supplies the pipe.
Liquid touches only the pipe that the user provides. Vapors above the liquid reach NBR and polyamide components, and the clamp-style NDT-2080 adds zinc-plated steel. The sensor housing is black polyamide. Matching the pipe material to the chemical media is how compatibility is achieved.
The contact is a single-pole, double-throw (SPDT) mechanical type with a maximum rating of 6 A resistive at 250 VAC. Three terminals are provided: terminal 1 is common, terminal 2 is normally closed, and terminal 3 is normally open. Cable entry is through a PG 16 gland.
Media temperature may range from 15 °F up to 185 °F (-9 °C to 85 °C). The enclosure carries NEMA 4 protection. To keep the unit watertight, the lid and the gland need to be fully tightened once the wiring is complete.
Mount the switch higher than the tank top, with its pipe reaching down into the vessel. This position keeps fluid away from the internals; flooding them can permanently shift the setpoint or cause other damage. Rigid support is required for the switch and the pipe alike.
Very little. The sensing mechanism stays out of the media, so the recommended upkeep is an occasional check that electrical connections remain tight and free of corrosion. With media that leave a coating on tanks and piping, taking the pressure pipe off for periodic cleaning is also recommended.
Product Specifications
Wetted Parts Exposed to Liquid
User-Supplied Pipe
Wetted Parts Exposed to Air Pocket
NBR, Polyamide (Zn Plated Steel with Clamp Version)
Media
Any Compatible, Free-Flowing Liquid
Switchpoint
4" Above the Bottom of User-Supplied Tube
Switch Rating
SPDT, 250 VAC/6A max. (Resistive Load)
Product Features
Functions with Coating, Dirty, and Viscous Liquids
Documents
Software Downloads
There are no downloads to display at this time. If you think this is incorrect, please contact us and let us know the issue you are having.
Videos
There are no videos to display at this time. If you think this is incorrect, please contact us and let us know the issue you are having.
Accessories
There are no accessories to display at this time. If you think this is incorrect, please contact us and let us know the issue you are having.