What Is the KPH Compact Pressure Switch?
The KOBOLD KPH is a compact mechanical pressure switch for pneumatic and hydraulic applications, monitoring air, gases, lubricating oil, light fuels, and other compatible media across nine models from vacuum (-14 to 0 PSIG) to 580 to 6091 PSIG (40 to 420 bar). It has an adjustable setpoint, snap-action SPDT contact, and standard DIN 43 650A plug-in connector.
It has a rugged mechanical design and a long cycle life, rated for 10,000,000 (1 × 10⁷) mechanical cycles. The gold-plated contacts are designed to give mechanical reliability equal to that of a reed switch, and where reduced contact life is acceptable the KPH can switch AC loads up to 5 A, a capacity that exceeds that of reed switches.
KPH-8000 Series vs. KPH-8200 Series
The KPH-8000 series uses a diaphragm sensing mechanism for low to medium pressure monitoring of compatible gases or liquids, including air, gases, lubricating oil, and light fuels. The KPH-8200 series uses a piston sensing mechanism for high pressure monitoring of compatible liquids only, such as lubricating oil and light fuels.
KPH Pressure Ranges and Models
Burst pressure is 1160 PSIG (80 bar) for the KPH-8000 series, 5800 PSIG (400 bar) for the KPH-8221 through KPH-8223, and 8700 PSIG (600 bar) for the KPH-8224. Select a model so the desired switching point falls roughly mid-range. The deadband is fixed for each model.
- KPH-8021: -14 to 0 PSIG (-0.97 to 0 bar), vacuum, aluminum/FKM
- KPH-8022: 2.9 to 29 PSIG (0.2 to 2 bar), aluminum/FKM
- KPH-8023: 7.2 to 116 PSIG (0.5 to 8 bar), aluminum/NBR
- KPH-8024: 14.5 to 232 PSIG (1 to 16 bar), aluminum/NBR
- KPH-8025: 14.5 to 435 PSIG (1 to 30 bar), aluminum/NBR
- KPH-8221: 72 to 1015 PSIG (5 to 70 bar), aluminum/steel/NBR/PTFE
- KPH-8222: 145 to 2320 PSIG (10 to 160 bar), aluminum/steel/NBR/PTFE
- KPH-8223: 362 to 3625 PSIG (25 to 250 bar), aluminum/steel/NBR/PTFE
- KPH-8224: 580 to 6091 PSIG (40 to 420 bar), aluminum/steel/NBR/PTFE
Switch Type and Electrical Ratings
The KPH uses a snap-action SPDT switch with gold-plated contacts and a DIN 43 650A electrical connection. Minimum voltage is 6 VAC/VDC and maximum voltage is 250 VAC or 30 VDC. The maximum permanent resistive or inductive load is 0.1 A AC/DC, with switch life of at least 200,000 (2 × 10⁵) cycles.
AC loads up to 5 A can be switched with reduced contact life. The maximum switching rate is 100 per minute. Use an appropriately sized relay for larger loads; for inductive DC loads (relays, solenoids), a spark suppression diode or RC network is strongly recommended to maximize contact life.
Process Connections and Wetted Parts
The standard process connection is 1/4" FNPT. Options are G 1/4 on the KPH-8000 series (code G) and 7/16"-20 UNF (SAE #4) on the KPH-8200 series (code S). Wetted parts are aluminum with NBR or FKM on the KPH-8000 series, and aluminum, steel, PTFE, and NBR on the KPH-8200 series.
Media should be non-depositing with a maximum viscosity of 1000 cSt, and fully compatible with all wetted parts. Repeatability is ±4% of final value (±3% for vacuum).
Temperature, Ingress, and Mechanical Ratings
Ambient and fluid temperature ratings are 32 to 176°F (0 to 80°C) for the KPH-8021 and KPH-8022, 14 to 185°F (-10 to 85°C) for the KPH-8023, 8024, and 8025, and -13 to 176°F (-25 to 80°C) for the KPH-8200 series. The housing is rated IP65 and withstands vibration up to 15 g.
The body is 30 mm (1.18") square and 72 mm (2.83") tall, plus a 15.5 mm (0.61") process fitting with a 27 mm (1.06") hex; overall width with the plug connector is 75 mm (2.95"). Weight is 0.44 lb (0.20 kg).
Adjusting the KPH Setpoint
Either the upper or the lower switching point can be adjusted; the opposite point is then set by the fixed deadband. It can be changed during operation; use a pressure gauge for exact adjustment. Loosen the locking screw with a small slotted screwdriver, turn the adjustment screw with a 5 mm hex wrench, then retighten.
On positive pressure models, clockwise rotation raises the switching pressure; on the vacuum model, counter-clockwise rotation raises the switching point (higher vacuum).
KPH Installation Guidelines
Do not exceed the switch electrical ratings. For liquid media with pressure spikes or pulsating pressure, install a pressure snubber. Outdoor applications need sufficient weather protection; aggressive or salt-bearing atmospheres and drastic temperature variations are critical conditions.
Common Questions about KPH - Compact Pressure Switch
Process pressure acts on a diaphragm (KPH-8000 series) or a piston (KPH-8200 series). When pressure reaches the adjusted switching point, a snap-action SPDT microswitch changes state, and it returns at the opposite point defined by the fixed deadband. The contacts are gold plated and are wired through a DIN 43 650A plug connector.
Choose the model whose adjustment range places your desired switching point roughly in the middle. The KPH-8021 is the vacuum model (-14 to 0 PSIG, -0.97 to 0 bar); the KPH-8022 through KPH-8025 span 2.9 to 435 PSIG (0.2 to 30 bar); the KPH-8221 through KPH-8224 span 72 to 6091 PSIG (5 to 420 bar). Gases require the KPH-8000 series.
The SPDT contact is rated from 6 VAC/VDC up to 250 VAC or 30 VDC. Permanent resistive or inductive loads are limited to 0.1 A AC/DC, which gives a contact life of at least 200,000 cycles. Loads of up to 5 A AC can be switched if reduced contact life is acceptable. Use a relay for larger loads.
No. Each KPH model has a fixed deadband, so adjusting one switching point automatically sets the other. On the KPH-8021 the band is 2.17 to 2.61 PSI (0.15 to 0.18 bar); across the remaining KPH-8000 models it spans 2.9 to 72.5 PSI (0.2 to 5 bar), and on the KPH-8200 series 152 to 551 PSI (10.5 to 38 bar).
Every model ships with a 1/4" FNPT connection. KPH-8000 series units can be ordered with a G 1/4 thread instead (option G), and KPH-8200 series units with a 7/16"-20 UNF thread, also called SAE #4 (option S). On the electrical side, a Hirschmann connector with 1/2" NPT conduit replaces the standard plug under option C.
The KPH-8000 series handles compatible gases or liquids, and the KPH-8200 series compatible liquids only. Typical media are light fuels, lubricating oil, air, and other gases. Suitable media are non-depositing, no more viscous than 1000 cSt, and compatible with the aluminum, NBR, FKM, steel, or PTFE wetted parts of the chosen model.
The DIN 43 650A connector uses terminals 1, 2, and 3. On positive pressure models, 1-2 opens on rising pressure and 1-3 closes on rising pressure. On the vacuum model, 1-2 closes with increasing vacuum and 1-3 opens with increasing vacuum. Inductive DC loads call for spark suppression (diode or RC network).
The housing is rated IP65, but outdoor installations still need sufficient weather protection, especially in aggressive or salt-bearing atmospheres or where temperatures vary drastically. Where splashing liquids reach the adjustment end of the switch, order the EC splash protection cover or add it later as accessory KPH-PEC.
Ambient and fluid temperature share one rating per model. The KPH-8200 series is rated -13 to 176°F (-25 to 80°C). Within the KPH-8000 series, the two FKM models (KPH-8021 and KPH-8022) are rated 32 to 176°F (0 to 80°C), while the NBR models (KPH-8023 through KPH-8025) are rated 14 to 185°F (-10 to 85°C).
Product Specifications
Fittings
1/4" FNPT standard; optional G 1/4 (KPH-80xx) or 7/16"-20 UNF (KPH-82xx)
KPH-8000
Gases or Compatible Liquids
KPH-8200
Compatible Liquids Only
Repeatability
±4% of Final Value (±3% for Vacuum)
Switch
Adjustable, Snap-Action SPDT
Product Features
Ranges - Vacuum to 6091 PSIG
Suitable for Pneumatic or Hydraulic Applications
DIN 43 650A Plug Connector Standard
Documents
Software Downloads
There are no downloads to display at this time. If you think this is incorrect, please contact us and let us know the issue you are having.
Videos
There are no videos to display at this time. If you think this is incorrect, please contact us and let us know the issue you are having.
Accessories
There are no accessories to display at this time. If you think this is incorrect, please contact us and let us know the issue you are having.