MMA Insertion Temperature Sensor with Pt100 RTD and Optional 4-20 mA Transmitter
The MMA is an insertion temperature sensor that uses a Pt100 resistance element in a 316L stainless steel probe, available as a resistive sensor or with an integrated two-wire 4-20 mA transmitter. Paired with the optional AUF plug-on display, it is designed to provide an economical, compact digital thermometer.
The MMA features stainless steel construction, immunity to vibration, and IP65 protection. Process connections are threaded or Tri-Clamp®, and the electrical connection is a DIN 43650 or M12 connector.
MMA Temperature Ranges and Pt100 Sensor Classes
The standard MMA-0 measures from -90 to 300 °F (-70 to 150 °C). The MMA-H, which adds an extension for temperature isolation, measures from -90 to 480 °F (-70 to 250 °C). A cryogenic sensor type covers -320 to 212 °F (-198 to 100 °C). Other ranges are available on request.
The extension is used for process temperatures above 300 °F (150 °C). A maximum temperature of 750 °F (400 °C) is available on request.
- Sensor element: Pt100 conforming to IEC 751
- Sensor classes: Class A, 1/3 DIN, 1/10 DIN, or Class B cryogenic type
- RTD wiring: 2-wire, 3-wire, or 4-wire
- Accuracy: less than 0.5% of measuring span
Process Connections, Insertion Lengths, and Pressure Ratings
The MMA is available with fixed ¼" NPT or ½" NPT threads, G threads, a ½" NPT compression fitting (MMA-0 only), or Tri-Clamp® connections to DIN 32676 and ASME. The bulbs are designed for pressures up to 520 PSIG (36 bar) on threaded versions, depending on the process conditions.
- Tri-Clamp® maximum pressure: 230 PSIG (16 bar) or per clamp rating
- Tri-Clamp® sizes: DN10, DN15, DN20, DN25, DN40, DN50, ½", ¾", 1", 1½", and 2"
- Probe: 316L stainless steel, 6 mm (0.24 in) diameter
- Process connection material: 316L stainless steel
- Insertion lengths: ten standard lengths from 1" to 24" (25 to 610 mm), plus special lengths
- Also available without a process connection
Integrated 4-20 mA Transmitter and Electrical Connection
With the integrated transmitter, the MMA provides a two-wire 4-20 mA output from an 8 to 35 VDC supply. Temperature sensors with a transmitter are capable of transmitting measuring signals noise-free over long distances. The transmitter is built into the resistance thermometer inside a stainless steel housing.
The standard transmitter range is 32 to 212 °F (0 to 100 °C). A special range can be specified, and it should fall within the range of the selected sensor type. The minimum measuring span is 45 °F (25 °C). With a transmitter, the MMA-0 has a maximum range of -40 to 300 °F (-40 to 150 °C). Transmitter ambient temperature is -40 to 185 °F (-40 to 85 °C).
The transmitter range is configurable by PC with the Loop Link communication interface and configuration software. A cable with M12 connector is needed.
With the optional DIN 43650 electrical connector, the transmitter can be cable-connected or fitted with the AUF display. The M12 x 1 (4-pin) connector has the same cable-connection functionality. For M12 versions, 4-pin Micro-DC connector cables are available as accessories in 6 ft (1.8 m), 16 ft (4.9 m), and 32 ft (9.8 m) lengths.
AUF Plug-On Display for Local Temperature Indication
The optional AUF is a compact local electronic display that plugs onto the MMA and works with the two-wire 4-20 mA signal. It has a 4-digit red LED display and is programmed with two buttons through a menu. The AUF-1000 is the standard version, and the AUF-1001 adds an open collector for a limit contact.
- Digit height: 0.3" (7.62 mm)
- Indicating range: -1999 to 9999
- Voltage drop: ≤ 5 VDC
- Programmable settings: scaling of indicating range, decimal point, damping, fault indication, and optional switch point
- Protection: IP65
- Ambient temperature: 32 to 140 °F (0 to 60 °C)
Where Is the MMA Temperature Sensor Used?
The MMA is suitable for applications where processes involving fluids, solid bodies or materials, or gases require temperature recording and measurement. Common application areas include heating installation and furnace apparatus construction, machine construction and building installations, marine engineering, general industry, and the pharmaceutical industry.
The sensors are also suitable for use in chemical, petrochemical, and water applications.
Common Questions about MMA - Insertion Temperature Sensor
The MMA is a resistance thermometer. It works by using the continuous change in the resistance of a metal as temperature rises and falls. The resistance material is platinum, which is very stable and has very good repeatability, and its resistance increases as temperature rises. A Pt100 sensor has a nominal value of 100 Ω at 32 °F (0 °C).
The MMA-0 is the standard model, with an upper measuring limit of 300 °F (150 °C). The MMA-H has a 2" (50 mm) extension for temperature isolation, which raises the upper limit to 480 °F (250 °C). Both start at -90 °F (-70 °C). Only the MMA-0 is offered with the compression fitting.
The MMA transmitter is a two-wire device with a 4-20 mA current output and a power supply of 8 to 35 VDC. On alarm, the signal follows NAMUR NE43: 23 mA upscale or 3.5 mA downscale. Transmitter response time is 0.33 to 60 s, and versions with a transmitter use 3-wire RTD wiring.
With 2-wire sensor wiring, the lead resistance of the sensor causes a measurement error. With 3-wire wiring, lead resistance is negligible for connecting wires up to 82 ft (25 m). With 4-wire wiring, the lead resistance of the connecting wires is negligible. The 4-20 mA transmitter option is available only with 3-wire wiring.
Yes. Without the transmitter, the MMA is a resistive Pt100 temperature sensor with 2-wire, 3-wire, or 4-wire connection through either electrical connector. Storage temperature for sensors without a transmitter is -13 to 176 °F (-25 to 80 °C), and instruments in storage should be protected against humidity and dust.
Threaded MMA probes have a maximum pressure of 520 PSIG (36 bar), subject to process conditions. Clamp versions have a maximum pressure of 230 PSIG (16 bar) or the rating of the clamp itself. The 230 PSIG value applies across every clamp size, from DN10 through DN50 and from ½" through 2".
No. The MMA does not require maintenance or servicing, and repairs must be carried out only by KOBOLD. Deposits on the sensor or thermowell can cause wrong measured values and long response times, so deposits should be removed. Corrosion can occur when the composition of the medium is not as expected.
Wrong measured values with long response times can result from incorrect mounting geometry, such as a mounting depth that is too deep or heat dissipation that is too high. The temperature-sensitive area of the sensor must be inside the medium, and surfaces must be isolated. Sensor drift caused by over temperature requires replacing the probe.
Signal interference can be caused by stray currents from electric fields or by ground loops. Corrective actions are to use screened connecting cables and increase the distance to motors and power lines. For ground loops, eliminate potentials and use galvanically isolated transmitter supply isolators or transmitters.
Product Specifications
Measuring Range
MMA-0: -90...300 °F (-70...150 °C); MMA-H: -90...480 °F (-70...250 °C); cryogenic sensor type: -320...212 °F (-198...100 °C)
Max. Temperature
750 °F (400 °C), on request
Fittings
1/4" NPT, 1/2" NPT, Clamp DIN 32676 and ASME
Probe Material
316L Stainless Steel
Sensor
Pt 100 Class A, 1/3 DIN, 1/10 DIN or Cryogenic
Electrical Connection
DIN 43650 or M12x1 (4-pin)
Product Features
Stainless Steel Construction
Documents
Software Downloads
Videos
There are no videos to display at this time. If you think this is incorrect, please contact us and let us know the issue you are having.
Accessories
There are no accessories to display at this time. If you think this is incorrect, please contact us and let us know the issue you are having.