The KOBOLD DUC is a clamp-on ultrasonic flow meter for liquids that measures flow from the outside of the pipe, with no contact with the process media. Two clamp-on transducers cover pipe diameters from 3/8 inch to 20 feet and flow velocities to ±98 ft/sec in both directions, with accuracy up to 1% of reading. The meter is offered as the portable, battery powered DUC-MP and as the stationary, wall mounted DUC-MF. Because nothing touches the flow, the DUC is designed for media that might damage the wetted sensors of other technologies and to install without pipe cutting or process shutdown.
How the DUC Measures Flow
The DUC operates on the acoustic time-of-flight principle. Two clamp-on ultrasonic transducers mounted on the pipe exchange acoustic signals through the moving liquid. Flow shortens the transit time of the signal traveling with it and lengthens the return transit time; the transmitter calculates average flow velocity from that difference and the path length.
The transmitter emits a coded signal pattern and uses only received signals that correlate with the original, an evaluation that lets the meter handle media carrying gas bubbles or solids within certain limits. A digital signal processor (DSP) computes the time-of-flight at high sampling rates; the measurement is very precise, drift free, and maintenance free, with no recurring calibrations. Reynolds compensation corrects for media viscosity, and the AFC algorithm adjusts for changing media temperatures without transducer movement.
Portable and Stationary Versions
Two flow transmitters are available. The portable DUC-MP runs approximately 22 hours per battery charge or on line power, includes a 4 GB data logger, and ships in a hard-shell case. The stationary DUC-MF is wall mounted and runs on 90 to 240 VAC, with 18 to 36 VDC optional.
- DUC-MP (portable): one measuring channel, aluminum and ABS housing, IP40 protection, BNC connections, and CSV data files for common office programs.
- DUC-MF (stationary): one or two measuring channels, ABS housing, IP65 protection, screw terminals, plus optional data logger and two optional 4-20 mA inputs.
- 2-channel operation: the DUC-MF 2-channel version measures two points or one common metering point and supports CH1+CH2, CH1-CH2, and (CH1+CH2)/2 operations; opposite mounting is designed to raise accuracy and enable redundancy.
Transducers and Pipe Sizes
Three transducer families match the pipe: the 4 MHz DUC-Wx40 for 3/8 inch to 4 inch pipe, the 1 MHz DUC-Wx10 for 1-1/4 inch to 16 inch pipe, and the 0.5 MHz DUC-Wx05 for 8 inch to 20 foot pipe, each in portable and stationary versions with IP68 protection.
All transducers use PEEK and aluminum construction and operate at media temperatures from -40 to 300 °F (-40 to 149 °C); the portable 0.5 MHz unit is rated to 176 °F (80 °C) with textile tightening straps and to 300 °F with a one-time-use stainless steel strap. V-mode mounting is standard, Z-mode suits large pipes or high acoustic damping, and W-mode serves pipes under 1-1/4 inch. Steel, plastic, and other pipe materials with ultrasonic conductive properties are supported.
Accuracy Across the Measuring Range
Accuracy depends on pipe size and velocity. From 2 inch pipe upward, the DUC measures within ±0.065 ft/sec up to 6.56 ft/sec and within 1% of reading from 6.56 to 98.42 ft/sec. Readings hold 1.5% on 1 to 2 inch pipe and 2.5% on 3/8 to 1 inch pipe in the upper band.
Outputs, Data Logging, and Heat Measurement
Both transmitters provide two 4-20 mA outputs plus pulse, relay, and micro USB connections, along with two Pt100 inputs for heat measurement. The DUC-MF accepts an optional RS232 or RS485 interface, and RS485 supports Modbus communication. Diagnostics include signal strength, SNR, and an oscilloscope display.
With two optional Pt100 sensors measuring feed and return temperatures, the transmitter calculates the thermal output and heat quantity of a heating circuit from temperature difference and flow.
Applications
The DUC serves flow, heat, and verification measurements across the water, energy, and process industries, in permanent installations and portable spot checks. Moving easily between points, it can also be used to check the readings of installed inline flow meters.
- Power plants: cooling water, district heating, pump protection, condensate and boiler feedwater
- Water and wastewater: treatment plant inflow and outflow, drinking water networks, verification of water meters, distribution and consumption, leakage detection
- Facility management: hot and cold water, cooling and air conditioning systems, energy efficiency optimization, pump control
- Chemical and petrochemical: crude and light oil, raw water and wastewater, aggressive and toxic media, thermal oil heat carriers
- Food and beverage: hygienic media measurement, heat volume in energy supply
Cost Advantages on Large Pipes
The DUC is designed to offer a cost advantage on large diameter pipes: it does not require extensive materials, significant shipping costs, or extensive construction and shutdown time to install. For smaller pipes, KOBOLD also offers the DUK compact inline ultrasonic flow meter.
Other Ultrasonic Flow Meter Installation Types
KOBOLD also offers the DUK Compact Inline Ultrasonic Flow Meter that delivers a cost advantage for smaller process pipe diameter applications.
Common Questions
Two transducers mounted on the outside of the pipeline work alternately as transmitters and receivers, sending ultrasonic signals at each other through the liquid. The resulting difference in the two signal propagation times is proportional to the flow rate and is used together with the pipeline geometry to calculate flow.
The transducer program spans 3/8 inch through 20 foot pipe, split across three frequencies. 4 MHz transducers fit 3/8 inch through 4 inch pipe, 1 MHz transducers fit 1-1/4 inch through 16 inch pipe, and 0.5 MHz transducers fit 8 inch through 20 foot pipe.
The DUC measures ultrasonically conductive liquids, from drinking water and wastewater to crude oil, light oil, thermal oils, and aggressive or toxic media. Cross correlation signal evaluation enables signal detection even at a low signal-to-noise ratio, and measurements with gas input or solid load of the medium are possible within certain limits.
Each transmitter carries two 4-20 mA outputs, one pulse output, one relay, and a micro USB port, plus two Pt100 inputs. On the stationary DUC-MF, the 2-channel version doubles the pulse and transducer connections, and an optional interface card adds RS232 or RS485 with Modbus support.
Battery operation is approximately 22 hours per charge, and the unit can also run from its 100 to 240 VAC wide range power supply. Data logging is standard, with 4 GB of integrated storage, a memory cycle adjustable between 1 second and 24 hours, and CSV files for easy transfer.
Yes. Connect two optional Pt100 temperature sensors on the feed and return lines of a heating circuit, and the transmitter combines the temperature difference with the flow rate to determine thermal output and heat quantity. On the 2-channel DUC-MF, heat measurement is supported in the (CH1+CH2)/2 operation mode.
The pipe must be completely filled at the transducer mounting positions, since measurement of partially filled pipes is not possible. Observe recommended straight runs, such as 10 pipe diameters upstream and 5 downstream of a 90 degree bend, and offset the transducers about 45 degrees from the horizontal plane on horizontal piping.
Yes, on request. The stationary transmitter can be ordered with ATEX Exd approval suitable for Zone 1 and Zone 2, and stationary 1 MHz and 0.5 MHz transducers offer a matching Ex option. The approval is not offered for 4 MHz transducers or for the portable version.
Select the stationary or portable transmitter, then transducers matched to pipe size and process characteristics. Transmitter codes set version, channels, supply, Ex approval, language package, and options such as RS232, RS485, or data logger. Transducer codes set version, frequency, Ex approval, and cable length up to 250 meters; the 2-channel transmitter needs two pairs of identical stationary transducers.
Product Specifications
Measurement Principle
Time-of-flight w/DSP (Transit Time Principle)
Flow Velocity Range
0...±98 ft/sec
Pipe Size Range
3/8"...20 Feet
Temperature Range
-40...300 °F (150 °C)
Accuracy
up to 1% of Reading
Product Features
Easy-to-read User Interface with LED Backlight, QVGA Display
Quick-Mount-System with Space Bar for Ultrasonic Transducers, 1 and 4 MHz
DSP Technology Reduces Signal Echoes and Dispersion Effects, Having a Positive Effect on the Signal to Noise Ratio
Portable and Stationary Versions Available
Applications within Power Plants, Water/Wastewater and Chemical Processing Industries
Certifications/Approvals: ATEX
Documents
Software Downloads
There are no downloads to display at this time. If you think this is incorrect, please contact us and let us know the issue you are having.
Videos
There are no videos to display at this time. If you think this is incorrect, please contact us and let us know the issue you are having.
Accessories
There are no accessories to display at this time. If you think this is incorrect, please contact us and let us know the issue you are having.